High Sensitivity Regulators

 Impact RM high sensitivity regulators are uniquely suited for point of use applications requiring precise regulation at pressure differentials less than 5 psid. The unique constant bleed internal pilot arrangement provides for superior adjustment resolution with no delay or overshoot. Droop is held to approximately 3 psi throughout the entire rated air flow and repeatability is +0.5 psi. Air bleed is less than 5 scfh and inaudible.

 

Full Size

Port

NPTF

Diag

Model

Primary

Pressure

Secondary

Pressure

Dim (max)

inches A

Dim (max)

inches B

Dim (max)

inches C

Depth

Weight

1/4

3/8

1/2

3/4

CR200

CR300

CR400

CR600

250 psi

15-100 psi

3 1/2

4 3/16

1 5/16

2 25/32

31 oz

High Capacity

Port

NPTF

Diag

Model

Primary

Pressure

Secondary

Pressure

Dim (max)

inches A

Dim (max)

inches B

Dim (max)

inches C

Depth

Weight

3/4

1

1 1/4

1 1/2

CR650

CR850

CR1050

CR1250

250 psi

15-100 psi

4 9/16

4 7/8

4 9/16

5

1 15/16

1 11/16

2 13/16

30 oz

36 0z

Option: High Capacity spring range 15-200 psi

Note: CR Model regulators will control to a minimum secondary pressure of 15 psi and will not shut off tight.


| Home Page | Products | Audits | Glossary of terms | Money savers | CD ROM |

| LP Meter | Tip of the month | Trouble shooting | Seminars | Resources