4488-AM2

4488-AM2

Design Pressure:200 PSIG(13.7 Bar)
Reservoir Capacity:8 oz(.236 Liter)
Condensate level:Visible
Electrical:115V-1PH-60HZ
Dimensions (WxDxH): 3.5'' x 5.5'' x 7.5''89mm x 140mm x 190mm
Fluid Temp (Min - Max):35°F - 180°F1°C - 82°C
Inlet Connection:1/2'' NPT
Discharge Connection:1/4'' NPT
Weight:5 lbs.2.2 kg
Valve type:Solenoid

Suitable for unattended draining of compressed air dryers, aftercoolers, receivers and other pressure vessels.

NO AIR LOSS DRAIN
A stainless steel float assembly equipped with a magnetic reed switch rises with the fluid level until its upper limit is reached. At this level, the reed switch signals a solid state relay which in turn signals a solenoid valve to be energized. As the valve opens, the line pressure forces the fluid in the reservoir to exit. As the float lowers with the reservoir fluid level, a lower limit is reached causing the reed switch to signal the closing of the solenoid valve allowing NO AIR to escape

 

STANDARD FEATURES
* Reliable operation
* Low maintenance
* Manual draining test switch
* Solid state electronic control
* Translucent reservoir
* Low Capacity

 